Sangam: A Confluence of Knowledge Streams

Analyses of long term off-design performance strategy and operation of a high pressure ratio intercooled Brayton helium gas turbine cycle for generation IV nuclear power plants

Show simple item record

dc.creator Gad-Briggs, Arnold
dc.creator Pilidis, Pericles
dc.creator Nikolaidis, Theoklis
dc.date 2018-08-06T14:42:09Z
dc.date 2018-08-06T14:42:09Z
dc.date 2018-05-23
dc.date.accessioned 2022-05-25T16:37:33Z
dc.date.available 2022-05-25T16:37:33Z
dc.identifier Arnold Gad-Briggs, Pericles Pilidis and Theoklis Nikolaidis. Analyses of long term off-design performance strategy and operation of a high pressure ratio intercooled Brayton helium gas turbine cycle for generation IV nuclear power plants. Journal of Nuclear Engineering and Radiation Science, Volume 4, Issue, 4, September 2018, Article number 041014
dc.identifier 2332-8983
dc.identifier https//doi.org/10.1016/j.ijplas.2018.07.009
dc.identifier http://dspace.lib.cranfield.ac.uk/handle/1826/13383
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/182241
dc.description The Intercooled Cycle (IC) is a simplified novel proposal for Generation IV Nuclear Power Plants (NPP) based on studies demonstrating efficiencies of over 45%. As an alternative to the Simple Cycle Recuperated (SCR) and the Intercooled Cycle Recuperated (ICR), the main difference in configuration is no recuperator, which reduces its size. It is expected that the components of the IC will not operate at optimum part power due to seasonal changes in ambient temperature and grid prioritisation for renewable sources. Thus the ability to demonstrate viable part load performance becomes an important requirement. The main objective of this study is to derive Off-Design Points (ODPs) for a temperature range of -35 to 50°C and COTs between 750 to 1000°C. The ODPs have been calculated using a tool designed for this study. Based on results, the intercooler changes the mass flow rate and compressor pressure ratio. However, a drop of ~9% in plant efficiency, in comparison to the ICR (6%) was observed for pressure losses of up to 5% . The reactor pressure losses for IC has the lowest effect on plant cycle efficiency in comparison to the SCR and ICR. Characteristic maps are created to support first order calculations. It is also proposed to consider the intercooler pressure loss as a handle for ODP performance. The analyses brings attention to the IC an alternative cycle and aids development of cycles for Generation IV Nuclear Power Plants specifically Gas Cooled Fast Reactors (GFRs) and Very High Temperature Reactors (VHTRs).
dc.language en
dc.publisher ASME
dc.rights Attribution-NonCommercial 4.0 International
dc.rights http://creativecommons.org/licenses/by/4.0/
dc.subject circular supply chain
dc.subject circular economy
dc.subject sustainability perspectives of supply chains
dc.subject restorative processes
dc.title Analyses of long term off-design performance strategy and operation of a high pressure ratio intercooled Brayton helium gas turbine cycle for generation IV nuclear power plants
dc.type Article


Files in this item

Files Size Format View
performance_str ... lear_power_plants-2018.pdf 982.8Kb application/pdf View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse