Sangam: A Confluence of Knowledge Streams

Development and Characterization of Plasma-based Sources for Ambient Desorption/Ionization Mass Spectrometry

Show simple item record

dc.contributor Hieftje, Gary M
dc.creator Shelley, Jacob T
dc.date 2011-10-19T20:19:09Z
dc.date 2028-06-19T20:19:09Z
dc.date 2011-10-19T20:19:09Z
dc.date 2011
dc.date.accessioned 2023-02-21T11:18:26Z
dc.date.available 2023-02-21T11:18:26Z
dc.identifier http://hdl.handle.net/2022/13770
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/252930
dc.description Thesis (Ph.D.) - Indiana University, Chemistry, 2011
dc.description A number of atmospheric-pressure ionization sources for mass spectrometry has recently appeared in the literature to yield a field that is collectively referred to as Ambient Desorption/Ionization-Mass Spectrometry (ADI-MS). These sources include, among others, Desorption ElectroSpray Ionization (DESI), Direct Analysis in Real Time (DART), the Flowing Atmospheric-Pressure Afterglow (FAPA), and the Low-Temperature Plasma (LTP) probe. Collectively, these ADI-MS sources offer numerous advantages over conventional ionization sources, including direct analysis of solid, liquid, and gaseous samples, high ionization efficiency, and soft ionization. Additionally, their ability to analyze samples directly with no pretreatment dramatically reduces analysis times. The ultimate ambient ionization source would be one that is capable of desorbing and ionizing a broad range of analytes (polar, non-polar, small molecules, biopolymers, etc.) while being minimally influenced by matrix effects. While the plasma-based ADI-MS sources, such as FAPA, DART, and LTP, have been shown to be capable of efficiently ionizing a range of small molecules, few investigations have been aimed at understanding desorption and ionization processes or matrix effects that occur with them. At present, the performance and fundamental characteristics of the FAPA source, developed in our research group, and the LTP probe, developed at Purdue University, are being evaluated through optical and mass-spectrometric methods. The FAPA source consists of a direct-current, atmospheric-pressure glow discharge in a pin-to-plate configuration. A hole in the plate allows ionized and excited plasma species to interact directly with a sample, while physically and electrically isolating the discharge from the sample-introduction region. Conversely, the LTP probe is a high-voltage, alternating-current, dielectric-barrier discharge that interacts directly with a sample. While the fundamental processes governing these discharges are quite different, mass spectra produced with both sources are very similar. The major differences are in achievable detection limits and susceptibility to matrix effects, with the FAPA sources routinely performing better. Direct, fundamental comparisons among the FAPA source, the LTP probe, and DART are made.
dc.language en
dc.publisher [Bloomington, Ind.] : Indiana University
dc.subject Chemistry
dc.title Development and Characterization of Plasma-based Sources for Ambient Desorption/Ionization Mass Spectrometry
dc.type Doctoral Dissertation


Files in this item

Files Size Format View
Shelley_indiana_0093A_11189.pdf 7.408Mb application/pdf View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse