Sangam: A Confluence of Knowledge Streams

Improving the flood resistance of sewer systems through strategic positioning and design of flow controls

Show simple item record

dc.contributor Memon, Fayyaz Ali
dc.contributor Butler, David
dc.contributor Jarman, Daniel Stuart
dc.contributor Andoh, Robert Yaw Gyamfi
dc.creator Newton, Christopher John
dc.date 2016-09-05T11:31:12Z
dc.date 2016-05-18
dc.date 2016-09-05T11:31:12Z
dc.date.accessioned 2023-02-23T09:58:01Z
dc.date.available 2023-02-23T09:58:01Z
dc.identifier http://hdl.handle.net/10871/23300
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/256563
dc.description Sewer systems are designed and installed to convey stormwater and wastewater from areas where it is collected to a treatment works or a suitable discharge point into a natural watercourse. Over time, however, changes in climate, population growth and urbanisation increase the flows these sewer systems need to convey. This thesis discusses a method, and developed assessment framework, to propose solutions to address flood risk. The method involves iteratively simulating a sewer system and designing vortex flow controls and orifice plates into the sewer system. These passive flow controls are designed into the sewer system, whilst accounting for sub-catchment flood vulnerability scores, to attenuate potential flood volumes and make use of available storage capacities in the upstream sections of the sewer system. The flow control positioning method uses the SWMM 5 program to simulate the sewer system, a developed hyetograph generator for the rainfall inputs and a flow control design tool. The whole assessment framework was programmed in Microsoft Excel and VBA. Vortex flow controls and orifice plates were chosen as they require no power, have no moving parts and are self-activating. Vortex flow controls are primarily designed into the sewer system, over orifice plates, due to their higher mean flow-rate and reduced blockage risk due to the larger outlet diameters. Four sewer system models were used to demonstrate the application of the assessment framework, in which one model was hypothetical and three were anonymised. The smallest model consisted of 14 nodes and collected surface runoff from 1.5 hectares. The largest model consisted of over 280 nodes and was a combined sewer system from a town in the South-East of England. In the application of the assessment framework, it was shown that strategically positioning and designing passive flow controls into the sewer system can have a beneficial effect by reducing flood risk. In one case study, the flood resistance level of a sewer system was increased from a 1 in 3 year return period to a 1 in 108 year return period. In the largest case study, which was of a combined sewer system, the flood resistance level was increased from a 1 in 1 year return period to a 1 in 71 year return period. The results of the analyses also found that installing vortex flow controls, instead of orifice plates only, tended to achieve a greater increase in the flood resistance level. Comparison of the proposed solutions from the method to alternative flood alleviation methods shows that the strategic positioning of passive flow controls to be a competitive and feasible solution to reduce flood risk.
dc.description Hydro International
dc.language en
dc.publisher University of Exeter
dc.publisher Department of Engineering
dc.title Improving the flood resistance of sewer systems through strategic positioning and design of flow controls
dc.type Thesis or dissertation
dc.type Doctor of Engineering in Water Engineering
dc.type Doctoral
dc.type EngD


Files in this item

Files Size Format View
NewtonC.pdf 7.400Mb application/pdf View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse