Sangam: A Confluence of Knowledge Streams

In-Situ Remediation of Small Leaks in Water Pipes: Impacts of Water Chemistry, Physical Parameters and the Presence of Particles

Show simple item record

dc.contributor Civil and Environmental Engineering
dc.contributor Edwards, Marc A.
dc.contributor Sinha, Sunil Kumar
dc.contributor Becker, William
dc.contributor Grasley, Zachary
dc.contributor Triantafyllidou, Simoni
dc.creator Tang, Min
dc.date 2017-03-03T09:00:19Z
dc.date 2017-03-03T09:00:19Z
dc.date 2017-03-02
dc.date.accessioned 2023-03-01T08:08:12Z
dc.date.available 2023-03-01T08:08:12Z
dc.identifier vt_gsexam:9079
dc.identifier http://hdl.handle.net/10919/75222
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/276293
dc.description Aging and leaking water infrastructure wastes water resources and creates public health risks. Upgrading of potable water systems represents a large financial burden for water utilities and private property owners. The conventional approaches of repair, rehabilitation and replacement are very effective, but will take decades to implement even if a financial commitment to do so was made immediately. A novel approach of in-situ remediation of leaks, achieved by harnessing the ability of water or pipe to repair leaks via clogging, could potentially reduce leak rates and extend the lifetime of existing infrastructure at relatively low cost and inconvenience. Physical clogging, precipitation and metallic corrosion were identified as major mechanisms of in-situ leak remediation in potable water pipelines. Autogenous repair (i.e., self-repair without added particles) of small leak-holes (150–"1000 μm) in copper and iron was validated in the laboratory at water pHs of 3.0–11.0, operating water pressures of 20–60 psi, upward and downward leak orientations, and for a range of water chemistries. In bench scale experiments, the time to repair of iron pipe leaks increased with leak size to the power of 0.89–1.89, and decreased with pipe wall thickness to the power of -1.9 to -1.0. The time to repair of copper pipe leaks increased with water pressure to the power of 1.7. Additionally, the waters with a higher DO and corrosivity as measured by RSI, significantly decreased the time to repair of carbon steel 400 μm leaks by 50–70%. The presence of chlorine dioxide significantly increased the fraction of repaired 200 μm copper pipe leaks by 3 times when compared to the control without any disinfectant. In the building scale study, the fraction of repaired iron pipe leaks decreased with the logarithmic leak size with a slope of -0.65 after one-year duration of experiments, while leak orientation and water pressure were not influential in time to or likelihood of repair for iron pipe leaks. Addition of calcium carbonate particles (~8.8 μ]m), silica particles (~29 μm) and wood ash particles (~160 μm) in Blacksburg, VA tap water at a water pressure of 10 psi increased the fraction of remediated iron pipe leaks of 280–1000 μm diameter sizes. Although the control condition with no added particles for 58 days resulted in remediation of 0/12 leaks, remediation rate increased to 1/12 with calcium carbonate particles, to 10/12 with silica particles and to 10/12 with wood ash particles. Leak size and particle size played an important role in controlling the remediation success rate. The strength of the in-situ leak repair was sometimes very strong and resilient. The sealing materials of leak-holes repaired at 20–60 psi could sometimes withstand a 100 psi water pressure without failure, demonstrating the potential of the approach to sustain aging and leaking infrastructure. In-situ leak repair can also occur naturally, and the success rate might be unintentionally altered by adjustment of chemistry or treatments that decrease or increase particulates.
dc.description Ph. D.
dc.format ETD
dc.format application/pdf
dc.format application/pdf
dc.format application/pdf
dc.publisher Virginia Tech
dc.rights In Copyright
dc.rights http://rightsstatements.org/vocab/InC/1.0/
dc.subject In-situ remediation
dc.subject water pipe leaks
dc.subject water chemistry
dc.subject physical parameters
dc.subject particles
dc.title In-Situ Remediation of Small Leaks in Water Pipes: Impacts of Water Chemistry, Physical Parameters and the Presence of Particles
dc.type Dissertation


Files in this item

Files Size Format View
Tang_M_D_2017_support_1.pdf 149.4Kb application/pdf View/Open
Tang_M_D_2017_support_3.pdf 120.8Kb application/pdf View/Open
Tang_M_D_2017.pdf 4.859Mb application/pdf View/Open