Sangam: A Confluence of Knowledge Streams

Investigation of Inlet Guide Vane Wakes in a F109 Turbofan Engine with and without Flow Control

Show simple item record

dc.contributor Mechanical Engineering
dc.contributor Ng, Fai
dc.contributor Burdisso, Ricardo A.
dc.contributor O'Brien, Walter F. Jr.
dc.contributor King, Peter S.
dc.contributor Dancey, Clinton L.
dc.creator Kozak, Jeffrey D.
dc.date 2014-03-14T20:15:48Z
dc.date 2014-03-14T20:15:48Z
dc.date 2000-08-17
dc.date 2000-08-31
dc.date 2001-09-14
dc.date 2000-09-14
dc.date.accessioned 2023-03-01T08:09:52Z
dc.date.available 2023-03-01T08:09:52Z
dc.identifier etd-08312000-14560008
dc.identifier http://hdl.handle.net/10919/28833
dc.identifier http://scholar.lib.vt.edu/theses/available/etd-08312000-14560008/
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/276535
dc.description A series of experiments were conducted in a F109 turbofan engine to investigate the unsteady wake profiles of an Inlet Guide Vane (IGV) at a typical spacing to the downstream fan at subsonic and transonic relative blade velocities. The sharp trailing-edge vanes were designed to produce a wake profile consistent with modern IGV. Time averaged baseline measurements were first performed with the IGV located upstream of the aerodynamic influence of the fan. Unsteady experiments were performed with an IGV-fan spacing of 0.43 fan chords. High-frequency on-vane pressure measurements showed strong peak-to-peak amplitudes at the blade passing frequency (BPF) of 4.7 psi at the transonic fan speeds. High-frequency total pressure measurements of the IGV wake were taken between the IGV and fan. Results showed that the total pressure loss coefficient of the time averaged IGV wake is reduced by 30% for the subsonic fan, and increased by a factor of 2 for the transonic fan compared to the baseline. Time resolved wake profiles for subsonic fan speeds show constructive and destructive interactions over each blade pass generated by the fan potential flow field. Time resolved wake profiles for the transonic fan speeds show that shock interactions with the IGV surface result in the wake shedding off of the vane at the BPF. Furthermore, the effectiveness of trailing edge blowing (TEB) flow control was investigated. TEB is the method of injecting air aft of the IGV to reduce the low pressure regions (deficits) in the viscous wakes shed by the vanes. Minimizing the IGV wakes reduces the forcing function on the downstream fan blades, thereby reducing high cycle fatigue. The TE span of the vane contains discrete holes at the axial centerline for TEB. Baseline results showed that TEB eliminates the IGV wake, while using only 0.03% of the total engine mass flow per IGV. TEB for the subsonic fan at the close spacing shows complete wake filling using the same mass flow as the baseline. TEB for the transonic fan shows a reduction of 68% in the total pressure loss coefficient, while requiring 2.5 times the mass flow as the baseline.
dc.description Ph. D.
dc.format application/pdf
dc.format application/pdf
dc.publisher Virginia Tech
dc.relation Kozakpart2.pdf
dc.relation Kozakpart1.pdf
dc.rights In Copyright
dc.rights http://rightsstatements.org/vocab/InC/1.0/
dc.subject Wake
dc.subject Fan
dc.subject Inlet Guide Vane
dc.subject Trailing Edge Blowing
dc.subject F109
dc.subject Transonic
dc.subject Flow Control
dc.subject Unsteady Stator-rotor
dc.title Investigation of Inlet Guide Vane Wakes in a F109 Turbofan Engine with and without Flow Control
dc.type Dissertation


Files in this item

Files Size Format View
Kozakpart1.pdf 5.899Mb application/pdf View/Open
Kozakpart2.pdf 1.618Mb application/pdf View/Open

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse