Sangam: A Confluence of Knowledge Streams

Mitigation of impedance changes due to electroporation therapy using bursts of high-frequency bipolar pulses

Show simple item record

dc.contributor School of Biomedical Engineering and Sciences
dc.creator Bhonsle, Suyashree P.
dc.creator Arena, Christopher B.
dc.creator Sweeney, Daniel C.
dc.creator Davalos, Rafael V.
dc.date 2016-01-15T17:02:18Z
dc.date 2016-01-15T17:02:18Z
dc.date 2015-08-27
dc.date 2016-01-15T17:02:18Z
dc.date.accessioned 2023-03-01T18:52:29Z
dc.date.available 2023-03-01T18:52:29Z
dc.identifier BioMedical Engineering OnLine. 2015 Aug 27;14(Suppl 3):S3
dc.identifier http://hdl.handle.net/10919/64461
dc.identifier https://doi.org/10.1186/1475-925X-14-S3-S3
dc.identifier.uri http://localhost:8080/xmlui/handle/CUHPOERS/281624
dc.description Background For electroporation-based therapies, accurate modeling of the electric field distribution within the target tissue is important for predicting the treatment volume. In response to conventional, unipolar pulses, the electrical impedance of a tissue varies as a function of the local electric field, leading to a redistribution of the field. These dynamic impedance changes, which depend on the tissue type and the applied electric field, need to be quantified a priori, making mathematical modeling complicated. Here, it is shown that the impedance changes during high-frequency, bipolar electroporation therapy are reduced, and the electric field distribution can be approximated using the analytical solution to Laplace's equation that is valid for a homogeneous medium of constant conductivity. Methods Two methods were used to examine the agreement between the analytical solution to Laplace's equation and the electric fields generated by 100 µs unipolar pulses and bursts of 1 µs bipolar pulses. First, pulses were applied to potato tuber tissue while an infrared camera was used to monitor the temperature distribution in real-time as a corollary to the electric field distribution. The analytical solution was overlaid on the thermal images for a qualitative assessment of the electric fields. Second, potato ablations were performed and the lesion size was measured along the x- and y-axes. These values were compared to the analytical solution to quantify its ability to predict treatment outcomes. To analyze the dynamic impedance changes due to electroporation at different frequencies, electrical impedance measurements (1 Hz to 1 MHz) were made before and after the treatment of potato tissue. Results For high-frequency bipolar burst treatment, the thermal images closely mirrored the constant electric field contours. The potato tissue lesions differed from the analytical solution by 39.7 ± 1.3 % (x-axis) and 6.87 ± 6.26 % (y-axis) for conventional unipolar pulses, and 15.46 ± 1.37 % (x-axis) and 3.63 ± 5.9 % (y-axis) for high- frequency bipolar pulses. Conclusions The electric field distributions due to high-frequency, bipolar electroporation pulses can be closely approximated with the homogeneous analytical solution. This paves way for modeling fields without prior characterization of non-linear tissue properties, and thereby simplifying electroporation procedures.
dc.description Published version
dc.format application/pdf
dc.format application/pdf
dc.language en_US
dc.rights Creative Commons Attribution 4.0 International
dc.rights http://creativecommons.org/licenses/by/4.0/
dc.rights Bhonsle et al.
dc.title Mitigation of impedance changes due to electroporation therapy using bursts of high-frequency bipolar pulses
dc.title BioMedical Engineering OnLine
dc.type Article - Refereed
dc.type Text


Files in this item

Files Size Format View
12938_2015_Article_979.pdf 1.358Mb application/pdf View/Open

This item appears in the following Collection(s)